Product thermal capacity: 4-35 t/h

Working pressure: 1.0-2.5 MPA

Outlet temperature: 184-350 ℃

Available fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil

Available industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries

  • Product introduction
  • Technical advantages
Introduction

steam boiler edr have a three-pass round coil structure. A conical coil is used for the effective protection of the furnace wall at the boiler end. This product is equipped with an advanced combustion device and is fully automated in operation. After the burner ignites the fuel, flame fills the round coil tubes and transfers heat by radiation through the tube wall (first pass). The high temperature flue gas gathers at the back door and then turns to the convection tubes section (second pass), where heat transfer takes place by convection. The flue gas gradually cools down here and flows to the front door, where it is reversed and goes into the third pass. After that, it enters into the chimney through the economizer and is released into the atmosphere.


steam boiler edr.This type of heater is delivered as a whole, and is installed on site, it only needs to connect thermal gas(oil) piping and electricity to start operation. The heater has four heating areas: furnace radiation heating area, the first convection tube bundle heating area, the second convection tube bundle heating area and economizer (waste heat boiler).

Digitized manufacture
  • The laying-off of steel tube adopts CNC 3D laser cutting machine.
  • The manufacture of round coil tube adopts CNC coil tube automatic production line. Once-forming and no need for plastic .
Full argon arc welding
  • The tube butt adopts argon arc welding technique and the seams will be done x ray real-time imaging, preventing unqualified seams from entering coil production line .
Easy operation
  • Heater is wholly assembled before delivery, it is easy for installation, debugging and operating.
  • Fully automatic operating, burning, liquid level of high level tank, outlet temperature and flow rate are adjusted automatically and self-protected.
  • The inlet and outlet with end flanges and flanged cover structure facilitate the installation and layout of tubeline in boiler house.
Less fuel consumption
  • Internal side adopts good insulation material, outside uses stainless steel plate, which can mostly reduce heat lost and make working environment better.
  • Multilayers closely spaced tube bundle and steel rod is used to seal and fix, completely eradicating short circuit of flue gas.
  • Before delivery, the residue moisture is removed completely, so the system draining period is reduced to 2 days from 12 days.
Safely operation
  • The inner coil tube has bigger flow rate, so it is more stable under high temperature operation.
  • Conical coil effectively protects the furnace wall at the end of heater and burner on the top.
Steam Boiler Sizi

Steam Boiler Sizi

6/12/2017 · Steam Boiler Sizing. EDR-Mbtuh. Steam Boiler Sizing. EDR-Mbtuh. Skip navigation Sign in. Search. ... Weil-McLain Oil-Fired Steam Boiler Live Fire Demo Piped In GLASS - Duration: 2:30.

Basic Steam Heat Revisited - Air Conditioning, Heati

Basic Steam Heat Revisited - Air Conditioning, Heati

2007/10/08 · An installer watches a gauge as he hydrostatically tests the boiler sections he just finished putting together for a steam heating system. (Courtesy of ... If you live and work anywhere near the Northeast corridor, you ...

The Ultimate Fulton Boiler Buying Guide: Find the Be

The Ultimate Fulton Boiler Buying Guide: Find the Be

Fulton Steam Products. Steam boilers are a necessary fixture in many industrial/commercial buildings, where they are used to maintain a hot water supply, power a heating system, or run a wide variety of heavy-duty equipment. For optimal performance and ef

Honest EDR & BTU calculations - Advice Needed - G

Honest EDR & BTU calculations - Advice Needed - G

I'm looking to educate myself so I don't get taken advantage of when I replace my old steam boiler. The old natural gas steam boiler has leaks in the tank.

How do I calculate the EDR of a steam radiator - JustAnsw

How do I calculate the EDR of a steam radiator - JustAnsw

Apr 07, 2010 · How do I calculate the EDR of a steam radiator. Hello, the steam rate is entirely a function of the application.. In other words the same radiator that draws 10 lbs of steam per minute in a 68F room will draw two or three times that in a r

Why undersized steam boilers waste fuel - Heating He

Why undersized steam boilers waste fuel - Heating He

6/23/2014 · Now, in sizing that replacement steam boiler, your job is to bring that 15,000 pounds of metal from room temperature to steam temperature, which in this case is 215 degrees F. (One square foot EDR equals 240 BTUH when there is 70-degree air ar

Inventum EDR 80 boiler | Feenst

Inventum EDR 80 boiler | Feenst

Inventum EDR 80 2,4 kW met groot vermogen is geschikt voor grote huishoudens met een groot warm water verbruik. U krijgt behalve veel, ook snel warm water.

How to size a condensate return unit - Xylem Applied Wat

How to size a condensate return unit - Xylem Applied Wat

It makes sense to convert the information you get from the engineer or customer into common terms across the system. When everything is said and done, what comes back from the boiler as condensate is .000496 gpm per 1 sq ft EDR. Rounding off, the boiler p

Find great deals on eBay for Steam Boiler in Steam Toys and Gam

Find great deals on eBay for Steam Boiler in Steam Toys and Gam

Steam Boiler Hand Pump in working order gland may want re packing. The boiler has not been fired up to test it, but it has clearly been cared for and all the moving parts move smoothly.

Proper steam boiler size — Heating Help: The Wa

Proper steam boiler size — Heating Help: The Wa

sizing steam boiler I would like to figure out whether the steam boiler I now have in my home is too small for the existing piping. The reason I am asking is because water flows over and out of the vent on top of the boiler when the system cools down.

Boiler Horsepower - Engineering ToolB

Boiler Horsepower - Engineering ToolB

Boiler horsepower - a power unit from the 19 th-20 th centuries - was used to rate the capacity of a boiler to deliver steam to steam engines.. A common definition of one boiler horsepower is the amount of energy required to produce 34.5 pounds (15.65 kg)

Inventum EDR 81 boiler | Feenst

Inventum EDR 81 boiler | Feenst

Inventum EDR 51 is een elektrische boiler voor 80 liter water. De boiler werkt automatisch 's nachts voor het goedkope nachttarief en blijft lang op temperatuur.

Commonly Used HVAC Formulae and Conversio

Commonly Used HVAC Formulae and Conversio

Commonly Used HVAC Formulae and Conversions Air Side Q Total = CFM x (h i ‐ h f) x 4.5 Btuh Q Sensible

Basics of Steam Generation - Energiteknik | K

Basics of Steam Generation - Energiteknik | K

The Basics of Steam Generation - 4 A simple boiler In order to describe the principles of a steam boiler, consider a very simple case, where the boiler simply is a container, partially filled with water (Figure 1). Combustion of fuel produce heat, which i

Boiler Formulas - debcoequipment.c

Boiler Formulas - debcoequipment.c

Boiler Formulas: Common Conversion Factors. Boiler HP x 34.5 Boiler HP x.069 Boiler HP x 33.4 Boiler HP x 139 BTU/Hour Output ч 240 EDR/1000 x 0.5 Lbs of Steam /Hr ч 500 = Lbs. of Steam per Hour = Evaporation Rate Gallons per Minute (GPM) = MBTU per Hour

Steam Capacity Conversion Table | Industrial Contro

Steam Capacity Conversion Table | Industrial Contro

Often it is necessary to convert a measure of capacity from one term to another. The conversion table will allow you to quickly convert various measures of capacity. The table and formulas can help you size and pick out components such as condensate pumps

Sizing boiler feed units vs. condensate return uni

Sizing boiler feed units vs. condensate return uni

Sizing boiler feed units vs. condensate return units Volume 3/ Issue 1/ March 2016. ... Rounding off, you can say the boiler puts out one half gallon per minute of water in the form of steam per 1000 sq ft. EDR. When the steam cools and turns back to wate

Deals - Corporate LiveWire - Corporate LiveWi

Deals - Corporate LiveWire - Corporate LiveWi

GCP Student Living plc Acquires Scape Brighton On 5 February 2019, GCP Student, the UK's first REIT focused on student residential assets, announced that the contract to acquire and forward fund Scape Brighton had gone unconditional.

EDR3RXD1B : Whirlpool EveryDrop Refrigerator Water Filt

EDR3RXD1B : Whirlpool EveryDrop Refrigerator Water Filt

Whirlpool EveryDrop Genuine OEM EDR3RXD2B Refrigerator Ice & Water Filter. Whirlpool EDR3RXD1B refrigerator filter is also referred to as Filter #3, 4396841P, and 4396710P.

Condensate Return and Boiler Feed Pumps “G” Seri

Condensate Return and Boiler Feed Pumps “G” Seri

steam heating systems to collect and quickly return condensate to the boiler or boiler feed unit. Pumping action is controlled by an integral float switch on simplex (one pump) units or mechanical alternator on duplex (two pump) units. Unlike boiler feed

부하계산 : 네이버 블로그 - blog.naver.c

부하계산 : 네이버 블로그 - blog.naver.c

다른 표현을 사용해주시기 바랍니다. 건전한 인터넷 문화 조성을 위해 회원님의 적극적인 협조를 부탁드립니다.