waste heat recovery from boiler

Industrial boilers

Product thermal capacity: 4-35 t/h

Working pressure: 1.0-2.5 MPA

Outlet temperature: 184-350 ℃

Available fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil

Available industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries

  • Product introduction
  • Technical advantages
Introduction

waste heat recovery from boiler have a three-pass round coil structure. A conical coil is used for the effective protection of the furnace wall at the boiler end. This product is equipped with an advanced combustion device and is fully automated in operation. After the burner ignites the fuel, flame fills the round coil tubes and transfers heat by radiation through the tube wall (first pass). The high temperature flue gas gathers at the back door and then turns to the convection tubes section (second pass), where heat transfer takes place by convection. The flue gas gradually cools down here and flows to the front door, where it is reversed and goes into the third pass. After that, it enters into the chimney through the economizer and is released into the atmosphere.


waste heat recovery from boiler.This type of heater is delivered as a whole, and is installed on site, it only needs to connect thermal gas(oil) piping and electricity to start operation. The heater has four heating areas: furnace radiation heating area, the first convection tube bundle heating area, the second convection tube bundle heating area and economizer (waste heat boiler).

Digitized manufacture
  • The laying-off of steel tube adopts CNC 3D laser cutting machine.
  • The manufacture of round coil tube adopts CNC coil tube automatic production line. Once-forming and no need for plastic .
Full argon arc welding
  • The tube butt adopts argon arc welding technique and the seams will be done x ray real-time imaging, preventing unqualified seams from entering coil production line .
Easy operation
  • Heater is wholly assembled before delivery, it is easy for installation, debugging and operating.
  • Fully automatic operating, burning, liquid level of high level tank, outlet temperature and flow rate are adjusted automatically and self-protected.
  • The inlet and outlet with end flanges and flanged cover structure facilitate the installation and layout of tubeline in boiler house.
Less fuel consumption
  • Internal side adopts good insulation material, outside uses stainless steel plate, which can mostly reduce heat lost and make working environment better.
  • Multilayers closely spaced tube bundle and steel rod is used to seal and fix, completely eradicating short circuit of flue gas.
  • Before delivery, the residue moisture is removed completely, so the system draining period is reduced to 2 days from 12 days.
Safely operation
  • The inner coil tube has bigger flow rate, so it is more stable under high temperature operation.
  • Conical coil effectively protects the furnace wall at the end of heater and burner on the top.
EasiHeat™| Heat Transfer Solutions | Spirax Sarco

EasiHeat™| Heat Transfer Solutions | Spirax Sarco

EasiHeat™ The Spirax EasiHeat™ is a complete, compact and energy efficient heat transfer solution, that will deliver a constant supply of instantaneous hot water at a stable temperature, on demand, for a range of domestic, heating and process hot water ap

Level Controls | Boiler Controls and Systems | Spir

Level Controls | Boiler Controls and Systems | Spir

Spirax Sarco Level Controls ensures your boiler water levels are be monitored accurately and safely. ... We use cookies to give you the best experience on our website. If you continue without changing your cookie settings, we ...

Green's Power | Economisers, waste heat boilers, la

Green's Power | Economisers, waste heat boilers, la

We design and manufacture customised waste heat recovery systems incorporating our economisers and waste heat boilers for a wide range of industrial sectors.Our industrial customers range from pulp and paper, steel and sugar mills to food processors, chem

Waste Heat Recovery Boilers for Lime Kiln | Reliable Ste

Waste Heat Recovery Boilers for Lime Kiln | Reliable Ste

6/25/2014 · Waste heat boiler of lime kiln is an efficient and reliable energy-saving product, which is mainly applied to cement making industry. According to different types and specification of lime kiln, technological process and production equipment,

Waste Heat Recovery & Oven Heat Recovery | Operational Gro

Waste Heat Recovery & Oven Heat Recovery | Operational Gro

Our waste heat recovery services involve the recovery and reuse of waste heat, making business and factory processes highly energy efficient. home solutions about us our people news contact case studies English Français Deutsch Español Nederlands Energy .

Waste Heat recovery Boiler (WHRB) – Engineering Equipment Ind

Waste Heat recovery Boiler (WHRB) – Engineering Equipment Ind

Waste heat found in the exhaust gas of various processes and from the exhaust stream of a conditioning unit which can be used to preheat the incoming gas. WHRB is. For preheated combustion air for heaters/furnaces nearby, For waste heat boiler to 100psi s

Waste Heat Recovery System (WHR

Waste Heat Recovery System (WHR

8 Waste Heat Recovery System (WHRS) for Reduction of Fuel Consumption, Emission and EEDI increasing the exhaust gas temperature before the boiler without using a power turbine. When applying the steam turbine (ST) as a stand-alone solution, the exhaust

A Review on Waste Heat Recovery in Industri

A Review on Waste Heat Recovery in Industri

A Review on Waste Heat Recovery in Industries Mr. Rupesh Suryavanshi1, Prof.A.D.Pitale2 M.Tech. (Heat & Power) Student1, Assistant Professor2 ...

Exhaust Heat Recovery Products | Cain Industri

Exhaust Heat Recovery Products | Cain Industri

Boiler Economizer Systems. Heat Transfer Systems for Boiler Exhaust Recovery Cain Industries offers an extensive selection of boiler economizers specifically designed to recover BTU exiting the exhaust stack and transfer it back into a desired heat sink.

Heat recovery - Carbon Tru

Heat recovery - Carbon Tru

Recuperator A device for waste heat recovery that works by counter-flowing hot gases and cold air through a heat exchanger. ... heat needs to be added by the boiler before the air is supplied to the space. The recovery efficiency of this type of system ..

Thermax power generation through waste heat recovery, pow

Thermax power generation through waste heat recovery, pow

Boiler Automation Solid Fuel Conversion Oil & Gas Conversion Upgrades Waste Heat Recovery System Customised Solutions Operation & Maintenance Packaged Boilers & Peripherals ...

Waste Heat Recovery Boiler| Industrial waste heat recovery syst

Waste Heat Recovery Boiler| Industrial waste heat recovery syst

One successful example is the waste heat recovery boiler, which can be situated above heat-generating equipment to generate steam that can drive electricity-producing generators. There are many ways in which waste heat can be lost, including flue gases, h

waste heat recovery from boiler blow do

waste heat recovery from boiler blow do

Boiler Working Animation Steam Boilers, Waste Heat Boilers, Thermal Liquid Heaters - Продолжительность: 4:58 ChemicalEngineering 487 076 просмотров. Waste Heat Recovery - Продолжительность: 2:10 VictoryEnergy 4 565 просмотров.

Waste Heat Boilers - Rentech Boile

Waste Heat Boilers - Rentech Boile

Fired Packaged Water Tube Boilers; Specialty Boilers; RENTECH Boiler Systems offers a full range of custom designed waste heat recovery boiler systems to meet your most demanding project requirements. RENTECH is an American boiler manufacturer known for i

US3861334A - Waste heat recovery - Google Paten

US3861334A - Waste heat recovery - Google Paten

In accordance with this invention a waste heat boiler 44 is positioned in the exhaust duct for the incinerator, downstream from the afterburner 34. The waste heat boiler is provided with a passageway 46 through which a heat exchange fluid may be directed

Waste Heat Recovery Boiler | Industrial Boilers Ameri

Waste Heat Recovery Boiler | Industrial Boilers Ameri

Waste Heat Recovery Boiler. Pipes filled with fluid, known as heat pipe exchangers, are able to transfer heat and are used in situations where hot exhaust from kilns, furnaces and boilers can be recovered and used to warm air or water. What are known as w

Cain Ind - Exhaust Heat Recovery and Steam Generat

Cain Ind - Exhaust Heat Recovery and Steam Generat

Exhaust heat recovery and steam generator systems for the engine cogeneration (CHP), boiler economizer and industrial heat exchanger markets. ... Versatility Since 1978, Cain Industries has produced high quality waste heat ...

Waste Heat Recovery Boiler - thermaxglobal.c

Waste Heat Recovery Boiler - thermaxglobal.c

Waste heat Recovery Boiler . Thermax manufactures hot water boilers in the range of 50,000 to 90,00,000 kcal per hour. The hot water boilers are designed to operate on various types of fuels such as heavy oil, light oil, gas, duel fuel, coal, husk and oth

Boilerroom Equipment | Products for the Commerci

Boilerroom Equipment | Products for the Commerci

Bruce, our on-line sales engineer, can help you select a HeatSponge economizer and generate predicted performance, pricing, and even a proposal on-line right now. ... Our units are built from the input of professionals with a ...

Energypack Boilers Pvt.l

Energypack Boilers Pvt.l

Mr. Yogesh Shah is having an experience over 45 years of running a 'BOILER INDUSTRY'. His support trains & motivates the HUMAN CAPITAL of the organization besides imparting practical & technical knowledge adding Value to the organization for consistent YE

Waste heat recovery boilers (WHRB) | Danstok

Waste heat recovery boilers (WHRB) | Danstok

Waste heat recovery boilers (WHRB) Design and development of special boilers and economizers for heat recovery of exhaust gases originating from chemical and industrial processes. The waste heat is recovered in single, double or triple-pass boilers provid