steam boiler equalizer line

Industrial boilers

Product thermal capacity: 4-35 t/h

Working pressure: 1.0-2.5 MPA

Outlet temperature: 184-350 ℃

Available fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil

Available industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries

  • Product introduction
  • Technical advantages
Introduction

steam boiler equalizer line have a three-pass round coil structure. A conical coil is used for the effective protection of the furnace wall at the boiler end. This product is equipped with an advanced combustion device and is fully automated in operation. After the burner ignites the fuel, flame fills the round coil tubes and transfers heat by radiation through the tube wall (first pass). The high temperature flue gas gathers at the back door and then turns to the convection tubes section (second pass), where heat transfer takes place by convection. The flue gas gradually cools down here and flows to the front door, where it is reversed and goes into the third pass. After that, it enters into the chimney through the economizer and is released into the atmosphere.


steam boiler equalizer line.This type of heater is delivered as a whole, and is installed on site, it only needs to connect thermal gas(oil) piping and electricity to start operation. The heater has four heating areas: furnace radiation heating area, the first convection tube bundle heating area, the second convection tube bundle heating area and economizer (waste heat boiler).

Digitized manufacture
  • The laying-off of steel tube adopts CNC 3D laser cutting machine.
  • The manufacture of round coil tube adopts CNC coil tube automatic production line. Once-forming and no need for plastic .
Full argon arc welding
  • The tube butt adopts argon arc welding technique and the seams will be done x ray real-time imaging, preventing unqualified seams from entering coil production line .
Easy operation
  • Heater is wholly assembled before delivery, it is easy for installation, debugging and operating.
  • Fully automatic operating, burning, liquid level of high level tank, outlet temperature and flow rate are adjusted automatically and self-protected.
  • The inlet and outlet with end flanges and flanged cover structure facilitate the installation and layout of tubeline in boiler house.
Less fuel consumption
  • Internal side adopts good insulation material, outside uses stainless steel plate, which can mostly reduce heat lost and make working environment better.
  • Multilayers closely spaced tube bundle and steel rod is used to seal and fix, completely eradicating short circuit of flue gas.
  • Before delivery, the residue moisture is removed completely, so the system draining period is reduced to 2 days from 12 days.
Safely operation
  • The inner coil tube has bigger flow rate, so it is more stable under high temperature operation.
  • Conical coil effectively protects the furnace wall at the end of heater and burner on the top.
Steam boiler piping - GIFFORD HENRY - Free Patents Onli

Steam boiler piping - GIFFORD HENRY - Free Patents Onli

2/26/2002 · A method for controlling water level in a steam boiler 11, the steam boiler 11 comprising a steam system piping 14 connected to a top portion of the steam boiler 11 and a condensate return pipe 12 connected to an equalizer pipe 13, one end of

Throwing Down the Hammer - Fixing a Noisy Steam Pi

Throwing Down the Hammer - Fixing a Noisy Steam Pi

Fixing a Noisy Steam Pipe ... the condensate can back up in the return line, and if the return line is just several feet above the water line in the boiler, one can have water hammer in that return line. ... The long nipple gives the returning condensate

1&( & Models STEAM BOILE

1&( & Models STEAM BOILE

normal water level line on left side of boiler. 6. Equip all boilers in gravity return systems with Hartford Loop as shown in Figure 6a and 6b page 10. 7. Piping vertical risers from boiler to header, risers must be minimum of 24" high above water line. 8

Adding Extra Water to an Existing Steam Boiler - G.W. Gi

Adding Extra Water to an Existing Steam Boiler - G.W. Gi

Adding Extra Water to an Existing Steam Boiler . ... like in vapor range. And a false water line must be added. This is alot of work and money and may not be the best option for adding water. ... I've seen these mounted in the 'A' dimension drip pipes, in

Equalization Line Placement - Valve engineering - Eng-Ti

Equalization Line Placement - Valve engineering - Eng-Ti

5/26/2010 · The service is hi-pressure steam, I plan to put the equalizer in the center line of the valve port rather then at the tob of the valve body since the valve will be in a dedicated steam service. My coworker is adament that I should place the eq

Steam boiler piping questions. equalizer is on the left

Steam boiler piping questions. equalizer is on the left

Steam boiler piping questions. equalizer is on the left of boiler , right hand side condensate return, no hartford loop. pip[ing from condensate goes up to lowwater cutoff level around boiler to steam riser, above condensate level. would this causes water

Top 10 facts about the Hartford Loop - Plumbing&Mechanic

Top 10 facts about the Hartford Loop - Plumbing&Mechanic

7/29/2014 · The end of the header drops vertically below the boiler’s water line and connects into the bottom of the boiler. We call this pipe the “equalizer” because it balances the pressure between the boiler’s steam outlet and condensate-return inlet.

STEAM Flashcards | Quizl

STEAM Flashcards | Quizl

After boiler, before equalizer line. System riser is piped to the... Main. Minimum height to header to normal water line is.. 24" Make up water should be piped in on ... 6-10" above steam line 15" before wet return. Boiler under 100,000. 1 1/4 minimum equ

Steam Coil Installation, Operation and Maintenan

Steam Coil Installation, Operation and Maintenan

Steam Coil Installation, Operation and Maintenance Guidelines for the installation, operation and maintenance of ... condensate line is elevated higher than the steam trap, then a pressure powered pump is required in order to drain coil at all times. ...

V11H Series PIPING RECOMMENDATIONS - Burnham Commerci

V11H Series PIPING RECOMMENDATIONS - Burnham Commerci

steam boiler notes: 1. all piping is schedule 40. ... equalizer close nipple hartford loop (req'd on gravity return system) 4 return 2 blowoff/drain valve (see note 3) rear of boiler 2" to 4" water line supply (see note 5) 5 riser 1 boiler model piping si

PDF BASIC STEAM HEATING SYSTEMS - gogeisel.c

PDF BASIC STEAM HEATING SYSTEMS - gogeisel.c

supply main must be above boiler water line for gravity flow of condensate back to the boiler. Dry Return— Return piping above the boiler water line that carries condensate back to the boiler. Equalizer— Piping from top of boiler to maintain pressure bala

Steam Heating Systems:Proprietary Systems | hvac machine

Steam Heating Systems:Proprietary Systems | hvac machine

10/18/2015 · When the motor-operated steam valves are used on the mains, the boiler connections should be arranged as shown in Figure 8-50. An equalizer line is required to equalize between the steam main and the return main when a vacuum forms in the for

Maintenance and Overhaul of Steam Turbines WGP42

Maintenance and Overhaul of Steam Turbines WGP42

IMIA – WGP 42 (05) 5 1. Introduction Steam turbines are utilized in numerous industries to drive boiler fans, boiler feed and water pumps, process and chiller compressors, blast furnace blowers, paper mill …

Operation, Maintenance and Installation Manual Condensa

Operation, Maintenance and Installation Manual Condensa

Operation, Maintenance and Installation Manual Condensate and Boiler Feed Units ... Discharge Line to Boiler Gate Valve Return Cond. Line Float Switch Gate Valve Strainer Cond. By-Pass Clean- ... steam traps, steam or water above 190°F may return to the c

Low-Pressure Steam Boiler Piping and Trim & Cross-Connecti

Low-Pressure Steam Boiler Piping and Trim & Cross-Connecti

Start studying Low-Pressure Steam Boiler Piping and Trim & Cross-Connection Control Awareness. Learn vocabulary, terms, and more with flashcards, games, and other study tools.

hot water loop on steam boiler - manalihoneymoonpackages.

hot water loop on steam boiler - manalihoneymoonpackages.

BASIC STEAM HEATING SYSTEMS - gogeisel.com. boiler steam 1st loop 2nd loop hartford loop steam supply main equalizer loop riser water line supply valve safety factor static head pressure drop drain 15" main vent drip connection wet return vent valve heati

Condensate Pot Equalisation Line - Refining, Hydrocarbo

Condensate Pot Equalisation Line - Refining, Hydrocarbo

1/28/2015 · Condensate Pot Equalisation Line - posted in Refining, Hydrocarbons, Oil, and Gas: What is the requirement of equalisation line in condensate pots? If we close the isolation valve in equalising line then what would happened? Please clear me ab

Deaerator White Paper for use with Industrial/Commerci

Deaerator White Paper for use with Industrial/Commerci

untreated water cause corrosion of the usual boiler and steam plant materials. The rate of the corrosive action is proportional to the amount of the gas present in the feedwater and is accelerated by high temperature. The primary purpose of deaerationis t

Taming Your Steam System - the

Taming Your Steam System - the "Hartford Loop" and Equaliz

taming your steam system - the "hartford loop" and equalizer piping Paul Mercier 02/23/2010 Heating In our preceding blog we addressed the subject "Plumbing Guys Plumb, Heating Guys Heat" to emphasize the need to employ complimentary skills in heating ins

What are Hartford loops and equalizer pipes? | Shop Yo

What are Hartford loops and equalizer pipes? | Shop Yo

(normally a 2 inch diameter pipe joining the steam header to the return line near the boiler) helped prevent water from backing out of the boiler by ensuring that the steam put equal pressure on the supply and return side of the boiler. The equalizer pipe

What are Hartford loops and equalizer pipes? | Shop Your W

What are Hartford loops and equalizer pipes? | Shop Your W

The equalizer pipe looks like a short circuit between the supply header and return pipe. Even with an equalizer, if a leak developed in the return piping below the water line, the boiler would run dry anyway.