Industrial boilers

Product thermal capacity: 4-35 t/h

Working pressure: 1.0-2.5 MPA

Outlet temperature: 184-350 ℃

Available fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil

Available industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries

  • Product introduction
  • Technical advantages
Introduction

requirements a steam generator boiler should fulfill have a three-pass round coil structure. A conical coil is used for the effective protection of the furnace wall at the boiler end. This product is equipped with an advanced combustion device and is fully automated in operation. After the burner ignites the fuel, flame fills the round coil tubes and transfers heat by radiation through the tube wall (first pass). The high temperature flue gas gathers at the back door and then turns to the convection tubes section (second pass), where heat transfer takes place by convection. The flue gas gradually cools down here and flows to the front door, where it is reversed and goes into the third pass. After that, it enters into the chimney through the economizer and is released into the atmosphere.


requirements a steam generator boiler should fulfill.This type of heater is delivered as a whole, and is installed on site, it only needs to connect thermal gas(oil) piping and electricity to start operation. The heater has four heating areas: furnace radiation heating area, the first convection tube bundle heating area, the second convection tube bundle heating area and economizer (waste heat boiler).

Digitized manufacture
  • The laying-off of steel tube adopts CNC 3D laser cutting machine.
  • The manufacture of round coil tube adopts CNC coil tube automatic production line. Once-forming and no need for plastic .
Full argon arc welding
  • The tube butt adopts argon arc welding technique and the seams will be done x ray real-time imaging, preventing unqualified seams from entering coil production line .
Easy operation
  • Heater is wholly assembled before delivery, it is easy for installation, debugging and operating.
  • Fully automatic operating, burning, liquid level of high level tank, outlet temperature and flow rate are adjusted automatically and self-protected.
  • The inlet and outlet with end flanges and flanged cover structure facilitate the installation and layout of tubeline in boiler house.
Less fuel consumption
  • Internal side adopts good insulation material, outside uses stainless steel plate, which can mostly reduce heat lost and make working environment better.
  • Multilayers closely spaced tube bundle and steel rod is used to seal and fix, completely eradicating short circuit of flue gas.
  • Before delivery, the residue moisture is removed completely, so the system draining period is reduced to 2 days from 12 days.
Safely operation
  • The inner coil tube has bigger flow rate, so it is more stable under high temperature operation.
  • Conical coil effectively protects the furnace wall at the end of heater and burner on the top.
Combustion Equipment for Steam Boilers | Energy Manageme

Combustion Equipment for Steam Boilers | Energy Manageme

In this article we will discuss about:- 1. Introduction to Combustion Equipment for Steam Boilers 2. Requirements of Combustion Equipment of Steam Boilers 3. Classification. Introduction to Combustion Equipment for Steam Boilers: The combustion equipment

PDF MC Steam Boilers and Turbines for Power Plants

PDF MC Steam Boilers and Turbines for Power Plants

1. POWER PLANT STEAM GENERATION 1.1 STEAM GENERATORS (BOILERS). For collateral reading and further detailed information, see (1) Steam Generation and Use, by Babcock & Wilcox, 1978 and (2) Combustion/Fossil Power Systems, by Combustion Engineering, Inc, 1

PDF Rules and Regulations for Boiler and Pressure Vessel Inspecti

PDF Rules and Regulations for Boiler and Pressure Vessel Inspecti

BOILER - A closed vessel in which water or other liquid is heated, steam or vapor is generated, steam or vapor is superheated, or any combination thereof, under pressure or vacuum, for use external to itself, by the direct application of energy from combu

CHAPTER TWO: Boiler Operation Maintenance & Safety Study Gui

CHAPTER TWO: Boiler Operation Maintenance & Safety Study Gui

A boiler should fulfill the following requirements: (i) Safety. The boiler should be safe under operating conditions. (ii) Accessibility. The various parts of the boiler should be accessible for repair and maintenance. (iii) Capacity. The boiler should be

Guide to Optimal Steam Generation | STERIS Universi

Guide to Optimal Steam Generation | STERIS Universi

What are the Industry Requirements? In the US, ANSI/AAMI ST79 provides guidance on steam quality for healthcare applications. According to the standard, “there are two common sources for steam used for sterile processing: hospital steam boiler systems and

Steam Generator - an overview | ScienceDirect Topi

Steam Generator - an overview | ScienceDirect Topi

Steam generators with Alloy 600MA tubes. WE and CE type steam generators with mill-annealed Alloy 600 tubes (600MA) have experienced a large variety of corrosion problems that initiated from both the primary side and secondary side of the tubes (e.g., Gor

Specifying a Steam Generator - babcock.c

Specifying a Steam Generator - babcock.c

steam temperature and pressure conditions, feedwater temperature and quality, fuel type(s) and characteristics, including ash properties, boiler efficiency requirements, emissions requirements, and; performance guarantees and test conditions. The specific

Textile Steam Atmospheric Boiler|GAS BOILER SA

Textile Steam Atmospheric Boiler|GAS BOILER SA

textile industries. Usually boilers are coal or oil fired. A boiler should fulfill the following requirements: (i) Safety. The boiler should be safe under operating conditions. (ii) Accessibility. The various parts of the boiler should be accessible for r

steam power plant and boilers.pptx | Boiler | Ste

steam power plant and boilers.pptx | Boiler | Ste

A boiler should fulfill the following requirements (a)Safety : The boiler should be safe under operating conditions. . (b) Accessibility : The various parts of the boiler should be accessible for repair and maintenance. (c) Capacity : The boiler should be

STEAM MOTOR VEHICLES - Car - Automobi

STEAM MOTOR VEHICLES - Car - Automobi

STEAM-GENERATOR REQUIREMENTS. In studying these apparent conflicts, we could see that all functions were closely related. That is, a water-level boiler held the temperature of the steam practically constant, with no possibility of temperatures high enough

Steam Boiler: September 20

Steam Boiler: September 20

Steam drum serves to separate the steam from a mixture of water and steam which enter into drum from evaporator circuit (boiler tube banks), to accommodate the steam produced, and serves as a "buffer tank" so that the steam pressure that will be distribut

Thermal design and optimization of a heat recovery ste

Thermal design and optimization of a heat recovery ste

On the other hand, a steam turbine is located after the heat recovery steam generator and the requirements of the steam cycle must also be fulfilled by the heat recovery steam generator. Satisfying the requirements of both the gas and steam cycles is nece

MC Steam Boilers and Turbines for Power Plants

MC Steam Boilers and Turbines for Power Plants

1. POWER PLANT STEAM GENERATION 1.1 STEAM GENERATORS (BOILERS). For collateral reading and further detailed information, see (1) Steam Generation and Use, by Babcock & Wilcox, 1978 and (2) Combustion/Fossil Power Systems, by Combustion Engineering, Inc, 1

Gas Steam Generators Manufacturer,Electrical Steam Generat

Gas Steam Generators Manufacturer,Electrical Steam Generat

GIRISON ENGINEERING SYSTEM - Professional & experienced Manufacturer and Supplier of Gas Steam Generators, Electrical Steam Generator, etc.,based in Mumbai, Maharashtra, India.

Why is it necessary to use a condenser in a steam powerplan

Why is it necessary to use a condenser in a steam powerplan

12/5/2016 · 4. The condensed steam temperature is always higher than the fresh water which is added as a make up water in a boiler, so the amount of the total heat supplied per kg of steam generation in a boiler is reduced to a great extent. 5. It minimiz

Steam Turbine Diagram With Parts - Best Place to Fi

Steam Turbine Diagram With Parts - Best Place to Fi

Steam turbine diagram with parts Its walls are covered with diagrams and maps showing you cant 3 d print a steam turbine mccormick said referring to the laser printing process that is being adapted to manufacture many small If you live and work anywhere n

DRDB: EDAQMD 229 INDUSTRIAL, INSTITUTIONAL, A

DRDB: EDAQMD 229 INDUSTRIAL, INSTITUTIONAL, A

A. PURPOSE: To provide a control measure to limit emissions of NOx from industrial, institutional, and commercial boilers, steam generators and process heaters in conformance with BARCT determinations approved by the California Air Resources Board to meet

Safe management of industrial steam and hot water boile

Safe management of industrial steam and hot water boile

Safe management of industrial steam and hot water boilers Water treatment As with all systems where water is heated there will be a potential for scaling. This can lead to a loss of efficiency or, in extreme cases, premature failure of the boiler due to e

requirements a steam generator boiler should fulfi

requirements a steam generator boiler should fulfi

requirements a steam generator boiler should fulfill. CHAPTER TWO: Boiler Operation Maintenance & Safety Study Guide. A boiler should fulfill the following requirements: (i) Safety. The boiler should be safe under operating conditions. (ii) Accessibility.

Steam turbine design for load-following capability a

Steam turbine design for load-following capability a

Steam CV at the inlet of a steam turbine controls the steam turbine’s load and rotation speed by adjusting the amount of steam volume flow rate (from the boiler) entering to the HP turbine. In order to respond to load changes or frequency fluctuations of

MASTER’S THESIS INFLUENCE OF MIXED FUELS COMBUSTION

MASTER’S THESIS INFLUENCE OF MIXED FUELS COMBUSTION

Influence of mixed fuels combustion on boiler operation Master’s thesis 2010 87 pages, 33 figures, 6 tables and 3 appendixes ... Drum type steam generator: Heat carrier circulates many times in the evaporator ... efficiency primarily refers to fulfill two